MDAS 16 Converter Board

2355552U
Used
Computed Tomography (CT)
GE HealthCare
GE HealthCare
GE HealthCare
N/A
Outright
Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Safe to use
  • Compact design
  • Serial transmission
  • Reliable performance

Other Buying Options


Condition: New

Product Overview

The Millennium Data Acquisition System (MDAS) Converter Board processes low current signals from 128 X-ray detector photodiode outputs and converts the signals into two digital serial streams. It integrates the low level current signals from 128 channels of a CT X-ray detector and convert it to 128 voltage signals and to 128 serial digital values. It receives control and configuration setup from the DAS Control Board (DCB) through a serial CAN interface bus. It performs a self-test on power up. The circuit board design includes a dedicated input anti-aliasing filter circuit (preamplifier) and floating point amplifiers. The Printed Wiring Board (PWB) has a flammability classification of 94V-1. The flammability rating of the fab is 94V-0. The board can be used for setting up the digital values for serial transmission. Relevant texts are printed on the labels surface for identification purposes and all the labels are securely affixed. It is RoHS compliant.

  • Additional Features

    • Flame retardant
    • Self-test on power up
    • RoHS compliant

    Return And Exchange

    GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.