text.skipToContent text.skipToNavigation

HFA-S Assembly with Spacer to Prevent Cable SWAP 5189221-3-R

5189221-3-R
Refurbished
Magnetic Resonance Imaging
GE HealthCare
GE HealthCare
GE HealthCare
Exchange - Return Defective

Core Exchange
Please ship this returnable part back within 30 calendar days of receipt of your original part shipment. Failure to return the part within 30 calendar days will result in an additional charge. We encourage you to check inventory prior to adding this item to your cart.

Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Enhanced durability
  • No special tooling is required for installation
  • Preventive maintenance is not needed for PCA boards
  • Full range protection

Other Buying Options


Condition: New

Product Overview

The HFA-S Assembly with Spacer to Prevent Cable SWAP is used in G3 GEMSPRO ACGD CAB ASM, ACGD CABINET ASSEMBLY W/SGA/SGAPS/GP which comes under the modality of MRI. The HFA-S (Switching Gradient Amplifier Hybrid) is an IGBT-based switching voltage amplifier that is utilized in the HFD-S subsystem, which has performance capabilities of 1400V and 320A. Three separate identical amplifiers (one for each axis) reside in an HFD-S subsystem and are powered by an ACGD-PS. The purpose of these amplifiers is to provide the voltage and current to the gradient coil during scanning. The inputs to the amplifier are voltage and current commands from the Gradient Processors (GP3) board. The amplifier has two floating outputs that are wired in series to provide the total gradient drive voltage. Also, internal to the amplifier is the current sensor, which provides a current feedback Signal to the GP3. The HFA-S is composed of: 2-IGBT Inverters and Choppers (Bus Bar boards), Output Filters, HFA Control board, Gate Driver board, Voltage Sense board, Back-Plane board, Current Sensor and Associated Cabling/Packaging. The GE product is an innovation and fit well into versatile customer needs. The part is diligently designed for superior performance and reliability. It is securely packed inside a high quality packing box to avoid physical damage during transit and labeled with details about the product, Quality Assurance (QA) seal and shipment details.

  • Additional Features

    • High corrosion resistance
    • Extremely high interrupting rating
    • All overloads clearing
    • Good wear and abrasion properties
    • ROHS compliant component

    Return And Exchange

    GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.

    Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.