text.skipToContent text.skipToNavigation

CCA, DCB, MAESTRO LU41600-R

LU41600-R
Refurbished
X-Ray
GE HealthCare
GE HealthCare
GE HealthCare
Exchange - Return Defective

Core Exchange
Please ship this returnable part back within 30 calendar days of receipt of your original part shipment. Failure to return the part within 30 calendar days will result in an additional charge. We encourage you to check inventory prior to adding this item to your cart.

Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Fast Ethernet Controller (FEC)
  • FlexCAN controller area network (CAN) module
  • Three universal asynchronous/synchronous receiver/transmitters (UARTs)
  • Inter-integrated circuit (I2C) bus controller

Other Buying Options


Condition: New

Product Overview

The Circuit Card Assembly (CCA) DAS Control Board is the detector control board (DCB) of the Maestro bone densitometer. This circuit card assembly is an embedded controller of the Maestro system. It is responsible for all Maestro detector control and support operations. It is intended to run as a master of the Maestro XMS CCA and slave to the host PC. This DCB is designed to take advantage of many of the on-chip modules of the MDF5280. The Detector Control Board (DCB) has many built-in features such as Inter-integrated circuit (I2C) bus controller, programmable software watchdog time, synchronous DRAM controller for two banks of SDRAM memory and up to seven chip-select signals. This DCB provides the enhanced diagnostic capability. This diagnostic tool allows service to distinguish detector failures from electronics failures (if test passes, electronics from eV ASIC are considered good). A second diagnostic circuit on board the DCB allows firmware to disconnect detector inputs ahead of the bipolar shaping stage and inject a test pulse on multiple channels. This diagnostic allows service to distinguish between detector and DCB failures. This assembly is compatible with GE's Lunar iDXA 2 system. The assembly will be shipped in suitable packaging to give adequate protection during transit.

LU41600-R

  • Additional Features

    • Queued serial peripheral interface (QSPI) module
    • Queued analog-to-digital converter (QADC)
    • Four channel direct memory access (DMA) controller
    • Programmable software watchdog timer
    • Interrupt controller
    • Clock module with integrated phase lock loop (PLL)
    • Synchronous DRAM controller for two banks of SDRAM memory
    • External-bus interface module for interfacing to memory and peripheral components
    • Up to seven chip-select signals
    • Miscellaneous general-purpose timers and timers for DMA support
    • Test access/debug port
    • System control module (SCM)

    Return And Exchange

    GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.

    Please note, cuffs, BP items, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion.