TDI Power Supply with CAN Board Interface for RAD - RoHS
2375101-11
2375101 2375101-11-H 2375101-11-R
New
X-Ray
GE Healthcare
GE Healthcare
GE Healthcare
Exchange - Return Defective

Core Exchange
Please ship this returnable part back within 30 calendar days of receipt of your original part shipment. Failure to return the part within 30 calendar days will result in an additional charge. We encourage you to check inventory prior to adding this item to your cart.

Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Compliance to the IEC 3rd edition safety and regulatory requirements.
  • Self-cooled
  • RoHS compliant

Other Buying Options


Condition: Refurbished
Condition: Used

Product Overview

The TDI Power Supply with CAN Board Interface for RAD system is being used to power the Apollo digital detectors in an X-ray system. The power supply system is RoHS compliant and complies to the IEC 3rd edition safety and regulatory requirements. The detector power supply systems is designed as a platform component for all GEHC Digital X-ray diagnosis systems as follows, Digital Radiographic System, Full Field Digital Mammography System and Digital Vascular System. The DPS is also designed as a platform power supply to perform in accordance with the following governmental, safety, and regulatory standards. The power supply is evaluated to the referenced UL, CSA and IEC standards by Nationally Recognized Test Laboratory (NRTL) to reflect GE Healthcare end use. The unit also bears the certification label of the NRTL. The system has the ability to read out the output voltage by USB or CANopen communication, then determines whether the output voltages needs to be trimmed to meet the system requirement. The power supply unit is self-cooled with or without an internal fan so that the design meets the temperatures and provides reliability. As long as the AC power is present, the fan speed increases with increased internal temperature. Fan speed should be controlled by internal temperature only and should run no faster than needed.

Compatible Products

Definium 6000

Definium 6000

Discovery XR650

Discovery XR650

Brivo XR DR-F

Brivo XR DR-F

Equivalent Part :

Below is more information on the equivalent parts. Parts without a hyperlink are listed for reference only and are not available for purchase online.

Equivalent partPart Details
2375101

This Next Generation Digital Detector Power Supply (DPS)

2375101-11-H The Detector Power Supply (DPS) provides regulated DC power
2375101-11-R

The Detector Power Supply (DPS) provides regulated DC pow

Return And Exchange

GE Healthcare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE Healthcare and return the item to GE Healthcare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.

Please note, cuffs, BP items and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE Healthcare’s sole discretion.